RPMTurbo
Specialists in Linear Flow Analysis

Standard Configuration 10: Unsteady Case 6

Case 6 is the most challenging subsonic case. This is because acoustic resonance occurs at the far-field downstream. The difficulty of Case 6 is evident in the fact that there is no consensus between the four methods. Note that the RPMTurbo solution is grid independent (resolution and location of far-field boundaries).